Customers
Ariel
Cooper
Fl Smidth
Sloan Brothers
Warren Cat


Ariel

DNFT performs monitoring and shutdown functions including No-Flow, Low-Flow or Excessive-Flow for divider-block lubrication systems. The DNFT is a completely enclosed solid state electronic device used to detect Slow-Flow and No-Flow conditions on in-line progressive lubrication systems. It incorporates a crystal oscillator to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. An easily replaceable internal lithium battery is the power source for the DNFT.

The DNFT is available in three different models with the ability to switch voltage up to 240 VDC.

Downloads (Product Data Sheets)

Instruction guide for each model of the DNFT is available for download. These files are in Adobe Acrobat (.pdf) format. These product data sheets are available to be printed out and reviewed for your convenience. You must view these downloads using Adobe Acrobat Reader, which is freely available to download at http://www.adobe.com.

Fast Internet Connections(pdf) Slow Internet Connections
A-10753 - Alarm - 3 minute
SBCO/Trabon O-Ring (4 pages)
A-10753 - page 1 A-10753 - page 2
A-10753 - page 3 A-10753 - page 4
A-10754 - Programmable
SBCO/Trabon O-Ring (5 pages)
A-10754 - page 1 A-10754 - page 2 A-10754 - page 3
A-10754 - page 4 A-10754 - page 5
A-10772 - Alarm - 45 second,
SBCO/Trabon O-Ring (4 pages)
A-10772 - page 1 A-10772 - page 2
A-10772 - page 3 A-10772 - page 4
A-10774 - Alarm - 3 minute,
SBCO/Trabon O-Ring, 120 VAC (4 pages)
A-10774 - page 1 A-10774 - page 2
A-10774 - page 3 A-10774 - page 4

Back to top


Cooper

DNFT performs monitoring and shutdown functions including No-Flow, Low-Flow or Excessive-Flow for divider-block lubrication systems. The DNFT is a completely enclosed solid state electronic device used to detect Slow-Flow and No-Flow conditions on in-line progressive lubrication systems. It incorporates a crystal oscillator to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. An easily replaceable internal lithium battery is the power source for the DNFT.

The DNFT is available in three different models with the ability to switch voltage up to 240 VDC.

Downloads (Product Data Sheets)

Instruction guide for each model of the DNFT is available for download. These files are in Adobe Acrobat (.pdf) format. These product data sheets are available to be printed out and reviewed for your convenience. You must view these downloads using Adobe Acrobat Reader, which is freely available to download at http://www.adobe.com.

Fast Internet Connections(pdf) Slow Internet Connections
Cooper (4 pages) Cooper - page 1 Cooper - page 2
Cooper - page 3 Cooper - page 4

Back to top


Fl Smidth (formerly Fuller)

DNFT performs monitoring and shutdown functions including No-Flow, Low-Flow or Excessive-Flow for divider-block lubrication systems. The DNFT is a completely enclosed solid state electronic device used to detect Slow-Flow and No-Flow conditions on in-line progressive lubrication systems. It incorporates a crystal oscillator to accurately monitor the cycle time of the lubrication system to enable precision timed shutdown capability. An easily replaceable internal lithium battery is the power source for the DNFT.

The DNFT is available in three different models with the ability to switch voltage up to 240 VDC.

Downloads (Product Data Sheets)

Instruction guide for each model of the DNFT is available for download. These files are in Adobe Acrobat (.pdf) format. These product data sheets are available to be printed out and reviewed for your convenience. You must view these downloads using Adobe Acrobat Reader, which is freely available to download at http://www.adobe.com.

Fast Internet Connections(pdf) Slow Internet Connections
FLS 33-1 120 VAC Relay FLS 33-1 120 VAC Relay
FLS LCC-Alarm Factory FLS LCC-Alarm Factory - page 1 FLS LCC-Alarm Factory - page 2
FLS LCC-Alarm Factory - page 3 FLS LCC-Alarm Factory - page 4

Back to top


Sloan Brothers
Proximity Switch

The proximity switch is a device that accurately monitors fluid or grease lubrication systems. It is manufactured using a custom machined stainless steel housing and a powerful magnet assembly built specifically for industrial use. It is easy to install and can be installed on any section on either side of the divider block. The SPS (Sealed Proximity Switch) is a completely sealed monitoring device.

Purge Gun

The lubrication purge gun is an easy-to-use, lever-action hand pump lubricator. It can be used to manually purge oil systems, test oil systems, and test the condition of a divider valve system. It's rugged cast iron head and aluminum chamber make it a very durable and long-lasting piece of equipment. The custom machined aluminum housing has slotted "windows" which enable the user to easily see the remaining oil level. This allows the user to refill the chamber before it is completely emptied, preventing air from being pumped into the system. The 40 inch hose assembly includes it's own built-in check valve that is rated for 5000 psi as shown on the liquid-filled pressure gauge.

Downloads (Product Data Sheets)

Instruction guide is available for download. These files are in Adobe Acrobat (.pdf) format. These product data sheets are available to be printed out and reviewed for your convenience. You must view these downloads using Adobe Acrobat Reader, which is freely available to download at http://www.adobe.com.

Fast Internet Connections(pdf) Slow Internet Connections
SB-PSX - Sealed Proximity Switch SB-PSX - Sealed Proximity Switch
SB Lube Purge Gun SB Lube Purge Gun

Back to top


Warren Cat

Downloads (Product Data Sheets)

Instruction guide is available for download. These files are in Adobe Acrobat (.pdf) format. These product data sheets are available to be printed out and reviewed for your convenience. You must view these downloads using Adobe Acrobat Reader, which is freely available to download at http://www.adobe.com.

Fast Internet Connections(pdf) Slow Internet Connections
CAT Relay Panel CAT Relay Panel
Throttle Throttle - page 1 Throttle - page 2
Wiring - CAT Truck System Throttle - page 3 Throttle - page 4
Throttle - page 5
CAT Install Instructions
Customer Install Instructions
Bill of Materials

Back to top